Commands - 111
STOP BIT
Tasking Statement
SYNTAX: STOP BIT task [,task] . . .
PURPOSE: To disable a bit that has previously been defined with an ON BIT statement and enabled with a
START BIT statement.
REMARKS: You can reenable the task by using the START BIT statement. You do not need to reexecute the ON
BIT statement.
See the Multitasking Chapter for more information.
RELATED: BIT function and statement, ON BIT, START BIT
EXAMPLE: 10 ON BIT 0,2,0 GOSUB 60
20 START BIT 0
30 PRINT "waiting..."
40 DELAY .5
50 GOTO 30
60 IF BIT(0,0) = 0 THEN PRINT"closed" ELSE PRINT "open"
70 STOP BIT 0
80 RETURN
ERROR: <Data out of range> – If task number > 7
<Data negative> – for task number